REAL Conversion (WORD)
Instruction Parameters
Supported PLC Series
| XPnA/1R | XPnB | XPnE | XPnF | CP3A/B/P/U CP4A~D/U | CPnE | CPnF | BP | PLC-S |
|---|---|---|---|---|---|---|---|---|
| ✓ | ✓ | ✓ | ✓ | - | - | - | - | ✓ |
Supported Data Registers
| M | X | Y | K | L | F | T | C | S | Z | R | Q | D | @D | Constant | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| S | ✓ | ✓ | ✓ | ✓ | ✓ | - | - | - | - | ✓ | - | ✓ | ✓ | ✓ | ✓ |
| D | ✓ | - | ✓ | ✓ | ✓ | - | ✓ | ✓ | - | ✓ | ✓ | ✓ | ✓ | ✓ | - |
Supported Flags
| Flag | Bit | Support |
|---|---|---|
| Error | F11.0 | ✓ |
| Zero | F11.1 | - |
| Carry | F11.2 | - |
Number of Steps
| Steps |
|---|
| 3 |
Operands
| Operand | Description |
|---|---|
| S | The first operand. Entries are REAL data registers or constants. The value range is -1.7014118e+38 ~ 3.4028237e+38 (2-127 ~ 2128). |
| D | The second operand. Entries are only WORD data registers. This is where the conversion is saved. |
Float Representation
| Mantissa | Exponent | Sign |
|---|---|---|
| Bit 0 ~ Bit 22 | Bit 23 ~ Bit 30 | Bit 31 |
Notice
Error Flag (F11.0) Notice
The error flag, F11.0, will be ON for one scan when the address of the data register assigned by @D exceeds the range of the data register, D. The range of the data register, D, is dependent on the CPU type.
F11.0 turns ON when the value of the data for converting S exceeds the value range of the data register D.
Instruction Behavior
The INT and INTP instructions behave as follows:
- When the data to be converted exceeds the range of -32,768 ~ 32,767, it overflows.
- No flag is turned ON.
- The 32-bit REAL value, S, is rounded down to the nearest ones place.