Skip to main content

Delete Table Data

Instruction Parameters

Supported PLC Series

XPnA/1RXPnBXPnEXPnFCP3A/B/P/U
CP4A~D/U
CPnECPnFBPPLC-S

Supported Data Registers

MXYKLFTCSZRQD@DConstant
DEV-
TBL----------
n--

Supported Flags

FlagBitSupport
ErrorF11.0
ZeroF11.1-
CarryF11.2-

Number of Steps

Steps
4

Operands

OperandDescription
DEVThe first operand.
Entries are WORD data registers or constants.
This is the storage location for the deleted value.
TBLThe second operand.
Entries are only WORD data registers.
This is the starting address for the table.
nThe third operand.
Entries are WORD data registers or constants.
This is the index to delete DEV from.
The value range is 1 ≤ n ≤ TBL data amount.

Notice

Error Flag (F11.0) Notice

The error flag, F11.0, will be ON for one scan when the address of the data register assigned by @D exceeds the range of the data register, D. The range of the data register, D, is dependent on the CPU type.

F11.0 turns ON when the data table exceeds the range of the corresponding data register.
F11.0 turns ON when the value of the data for n isn't in the range 1 ≤ n ≤ TBL data amount

Instruction Behavior

The FDEL and FDELP instructions behave as follows:

  • The value, DEV, is deleted at the index, n, from the table, TBL.
    • n must be greater or equal to 1 and less than or equal to the integer value representing the amount of data saved in the table, TBL.
    • The overall amount of data saved in the table, TBL, will decrease by 1.
  • The first value of TBL is an integer number representing the amount of data saved in the table, TBL.

Examples