Equal (WORD)

Comparison Uses

There are three types of comparison uses:

  • LD (Ladder Diagram)
  • AND
  • OR

The following compare instructions can be used as a:

  • WORD standalone execution condition (LD)
  • WORD and execution condition (AND)
  • WORD or execution condition (OR)

Instruction Parameters​

Supported PLC Series​

XPnA/1RXPnBXPnEXPnFCP3A/B/P/U
CP4A~D/U
CPnECPnFBPPLC-S
✓✓✓✓✓✓✓✓✓

Supported Data Registers​

MXYKLFTCSZRQD@DConstant
S1✓✓✓✓✓✓✓✓-✓✓✓✓✓✓
S2✓✓✓✓✓✓✓✓-✓✓✓✓✓✓

Supported Flags​

FlagBitSupport
ErrorF11.0✓
ZeroF11.1-
CarryF11.2-

Number of Steps​

Steps
3

Operands​

OperandDescription
S1The first operand.
Entries are signed WORD data registers or constants.

The signed value range is -32,768 ~ 32,767 (216).
The Hexadecimal value range is H0000 ~ HFFFF.

Only WORD values will be compared.
Only signed or Hexadecimal values will be compared.
S2The second operand.
Entries are signed WORD data registers or constants.

The signed value range is -32,768 ~ 32,767 (216).
The Hexadecimal value range is H0000 ~ HFFFF.

Only WORD values will be compared.
Only signed or Hexadecimal values will be compared.

Notice​

Error Flag (F11.0) Notice

The error flag, F11.0, will be ON for one scan when the address of the data register assigned by @D exceeds the range of the data register, D. The range of the data register, D, is dependent on the CPU type.

Examples​