Skip to main content

Degree Conversion

Instruction Parameters

Supported PLC Series

XPnA/1RXPnBXPnEXPnFCP3A/B/P/U
CP4A~D/U
CPnECPnFBPPLC-S
----

Supported Data Registers

MXYKLFTCSZRQD@DConstant
S-----
D-------

Supported Flags

FlagBitSupport
ErrorF11.0
ZeroF11.1-
CarryF11.2-

Number of Steps

Steps
3

Operands

OperandDescription
SThe first operand.
Entries are REAL data registers or constants.
This is the radian to convert to degrees.

The REAL value range is -2127 ~ 2128 (-1.7014118e+38 ~ 3.4028237e+38).
The radian value range is -6.28 ~ 6.28 (-2π ~ -2π).
DThe second operand.
Entries are only REAL data registers.
This is where the conversion is saved as degrees.

Float Representation

MantissaExponentSign
Bit 0 ~ Bit 22Bit 23 ~ Bit 30Bit 31

Notice

Error Flag (F11.0) Notice

The error flag, F11.0, will be ON for one scan when the address of the data register assigned by @D exceeds the range of the data register, D. The range of the data register, D, is dependent on the CPU type.

F11.0 turns ON when the value of the data for the calculation exceeds the data register assigned to S or D.

Instruction Result

The value resulting from the DEG or DEGP instruction is saved as a degree.
The conversion for degrees is:
Degrees = Radians × ( 180π )

Examples