Reset Carry Flag (0)

Instruction Parameters

Supported PLC Series

XPnA/1RXPnBXPnEXPnFCP3A/B/P/U
CP4A~D/U
CPnECPnFBPPLC-S

Supported Data Registers

MXYKLFTCSZRQD@DConstant
---------------

Supported Flags

FlagBitSupport
ErrorF11.0-
ZeroF11.1-
CarryF11.2

Number of Steps

Steps
1

Notice

Instruction Behavior

The CLC instruction behaves as follows:

  • The CLC instruction sets the carry flag, F11.2, to OFF (0), when the operation condition is ON (1).
  • When the operation condition of the CLC instruction is OFF (0) or ON (1), there is no change in the carry flag, F11.2.
Operational Differences

There are operational differences with the carry flag, F11.2, between the CPU types BP, XPnA/1R, CP3A/B/P/U, CP4A~D/U, and the CPU types PLC-S, XPnB/E/F, CPnE/F.
Refer to the carry flag, F11.2, for more information.

Examples