Open Contact - LD

Connection Requirements​

Supported PLC Series​

XPnA/1RXPnBXPnEXPnFCP3A/B/P/U
CP4A~D/U
CPnECPnFBPPLC-S
✓✓✓✓✓✓✓✓✓

Supported Data Registers​

MXYKLFTCSZRQD@DConstant
S✓✓✓✓✓✓✓✓✓--✓✓--

Supported Flags​

FlagBitSupport
ErrorF11.0-
ZeroF11.1-
CarryF11.2-

Number of Steps​

Steps
1

Operands​

OperandDescription
SThis is the BOOL data register.
This is the bit number to toggle the contact ON/OFF.

When the bit is 0, the contact is OFF.
When the bit is 1, the contact is ON.

Notice​

Contact Orientation

The LD contact orientation behaves as follows:

  • The LD contact orientation indicates the logical start by creating an ON or OFF execution condition based on the ON status of the assigned BOOL data register.
  • The LD contact orientation is connected to the bus bar or at the beginning of the logic block by ANB or ORB.

Examples​