- Support for eXT2 devices.
- Audio support for eXT2 devices.
- Note that XT1 devices (nXT/eXT) do not currently support audio.
- VNC server support (only for eXT2 devices) and built-in VNC client in the designer.
- Note that XT1 devices (nXT/eXT) do not currently support VNC.
- Updated GUI objects to use pixel-size font instead of point size.
- The default hostname for all Xpanel models is now
hmi.
- Fixed issues with Email authentication.
- Fixed misc. issues with switch/lamp previews and text alignment.
- Fixed issue with FTP start/stop server script.
- Fixed issue with IAM users not getting signed out after timeout.
- Fixed issue with modifying IAM permissions and groups at runtime through the User Management menu.
- Fixed issues with USB (Mini B or C) connection after rebooting the HMI multiple times.
- Fixed issues with the lowest brightness setting turning the screen off entirely on eXT4 devices.
- Fixed issues with misc. folder permission/access issues for FTP.
- Fixed issues with pressing change in the directory selection dialog causing the installer to crash.
- Added VNC viewer support.
- Updated GUI objects to use pixel-size font instead of point size.
- Updated project save process to better protect from project file corruption.
- Updated screen size options to include eXT2 devices.
- Fixed an issue with opening some corrupt projects and not notifying the user there was an error.
- Fixed an issue with incorrect switch/lamp label positioning when no state image is set.
- Fixed an issue with switch/lamp preview label not always showing.
- Fixed an issue with switch/lamp preview label positioning being incorrect.
- Clicking away from objects changes focus.
- Text size is now pixel size instead of point size.
- Numeric keys no longer replace text if the backspace key is pressed.
- Fixed an issue with the web server being enabled after Resetting User Data.
- Fixed an issue with (micro)SD card-related system tags not updating correctly.
- Fixed an issue where the project crashes if it doesn't match the screen size on Xpanel.
- Fixed an issue where the focus index was not working for pages with more than three objects.
- Fixed an issue with the FTP script not turning on/off the FTP service.
- Fixed an issue where system.execute doesn't start in the home directory.
- Fixed an issue with the on-screen keyboard appearing when pressing the hide/show password button on login dialogs.
- Fixed an issue with various dialogs showing the "?" button in the title bar.
- Fixed an issue where users are not signed out if idle session length passes.
- Fixed an issue with the frame monitor crashing if opened with a project without remote devices.
- Fixed an issue where changing pages with auto-scale enabled briefly shows the prescaled size.
- Fixed an issue with audio and file scripts causing the application to freeze if when run more than once.
- Fixed an issue where text alignment defaults are not set correctly.
- Fixed an issue where disabling touch enable allows users to run scripts on touch on Xpanel.
- Fixed an issue with recipes not encoding non-ASCII characters correctly.
- Fixed an issue where the User Management menu does not allow reading or modifying user emails.
- Fixed an issue where users could not click corner buttons if an alarm banner or notification is currently displayed.
- Fixed an issue with Tags in onTagValueChanged or onQualityChanged scripts not being subscribed to.
- Fixed an issue with sparkline not rendering NaN values correctly.
- Fixed an issue with gateway system tags being read-only.
- Fixed an issue where the content of the change password dialog gets cut off when error labels are shown.
- Fixed an issue where the Use Object Font option does not use font from the object.
- Fixed an issue with the alarm banner not scaling with window size.
- Fixed an issue where the alarm banner flickers.
- Fixed an issue with the system.openConfig script being restricted by permissions.
- Fixed an issue with the project crashing upon reading invalid NaN values from the gateway.
- Fixed an issue with the alarm label not being able to be selected in the alarm summary.
- Fixed an issue where modifying a user's permissions or groups removes a user's password.
- Fixed an issue with system.runScript losing references to calls in audit logs.
- General:
- Unicode support on Windows:
- Users who are not using a UTF-8 locale (only available on some Windows 10 versions) should now behave correctly.
- This mainly affected users who had a non-ASCII username or installation path.
- Email:
- SSL/TLS encryption support is now functional again.
- SMTP authentication will work again when no encryption is used when allowed by the SMTP server.
- Remote I/O drivers:
- ODVA EtherNet/IP Client:
- When running in "implicit" mode, the output data will be correctly updated when the driver is disconnected.
- Tags:
- The
:datalogger/<modelName>/enable: system tag now works correctly when the datalogger model name contains a /.
- The "replace" method for string encoding will now behave as intended (it was previously using the "skip" behavior).
- Datalogger:
- Fixed an issue that prevented CSV logging from working when a "weekly" timespan was used.
- Improved performance of CSV creation when there is less historical data than requested.
- Models with "manual" start option will now correctly respect trigger tag changes which also toggle the model's status.
- Alarms:
- Fixed a race condition that would sometimes cause alarms not to have their status updated.
- Alarms with "bitwise access" tags were particularly affected by this issue.
- Communication Drivers:
- OPC UA Client Driver:
- Enable/disable support has been added.
- Fixed a crash that could occur when monitoring a node with a NULL value.
- ODVA EtherNet/IP Client Driver:
- Enable/disable support has been added.
- When parsing the response of a string element read request, the driver will now correctly assert the response size before processing the data.
- There were some cases (usually involving string data) that our previous assertion allowed, which could result in the driver crashing.
- Implicit mode now has support for frame monitoring.
- Allen Bradley E/IP Client driver:
- When using the message type "tag", read requests for array elements with multiple services enabled will now behave as expected.
- Cimon UA Net Client and UA Bus Master Drivers:
- Fixed an issue where using continuous non-boolean tags in a digital memory area (X, Y, M, L, K, and F) resulted in incorrect addresses being used.
- Sparkplug 3 Edge Node driver:
- Fixed a crash specific to the eXT2 caused by the LP64 data model handling.
- Datatype conversions were overhauled to support the LP64 data model used by the eXT2 devices.
- Floating point values representing a NaN value will now be sanitized into a "quiet" NaN.
- This should help avoid undesired behavior on external applications that interact with one of the gateway's client/server drivers.
- This applies to all floating-point values used for tags, regardless of the value's origin.
- The recipe response/notification message was updated to be less verbose.
- Added support for eXT2 devices.
- VNC on eXT2.
- Thai font.
- Disabled most Weston built-in hotkeys.
- The default project now resizes automatically to fit the screen size.
- The hostname for all Xpanel models is now
hmi.
- Resetting user data no longer changes the default language.
- MAC address label styling.
- File dialogs were replaced with nondialog equivalents.
- Minor improvements were made to specify a delay time on the watchdog page.
- Settings app keyboard layout improvements.
- Fixed an issue where the eXT04 refresh rates were too high.
- Fixed an issue where rebooting the device 11 times disables the USB connection for 24 hours.
- Fixed an issue with second DNS not being set on User Data Reset.
- Fixed an issue where setting the lowest brightness level can turn off the backlight altogether.
- Fixed an issue with network configurations not being set correctly after updating via SWU.
- Fixed an issue with users not having write access on FTP.
- Fixed an issue with home and FTP directories not being reset on User Data Reset.
- Fixed an issue where FTP passwords are not preserved on SWU.
- Fixed an issue where dimmer settings are shown even if dimming is disabled.
- Fixed an issue with tab order in the settings app.
- Fixed an issue where the on-screen keyboard backspace does not repeat when holding keys.
- Fixed an issue with the on-screen keyboard not triggering the buzzer.
- Fixed an issue where the on-screen keyboard cannot input keys when interacting with a dropdown.
- Fixed an issue where the user cannot reset user data if a project with a persistent alarm or data logger exists.
- Fixed an issue where the on-screen keyboard covers the focused input field on the settings app.
- Fixed an issue with the on-screen keyboard using a nonkeypad layout for numeric fields on the settings app.
- Fixed an issue where the portal can crash if starting and stopping projects too fast.
- Fixed an issue with the portal restarting the application on stop requests.
- "Existing Version Detected" Dialog when upgrading or downgrading.
- Support for the vncviewer feature.
- Fixed an issue where pressing change in the directory selection dialog crashed the installer.